 Detcon Model Series 700 Gas Detection Sensors

"Environmentally Bulletproof"

  • Water-Proof
  • Corrosion-Proof
  • Vibration-Proof
  • Multi-Layer Surge Protection
  • Pre-emptive Fault Diagnostics

Detcon Model Series 700 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. The sensors are specifically designed for harsh and extreme locations. This new and superior level of environmental durability in sensor design includes an electropolished 316 stainless steel housing, multi-layered transient spike protection circuitry and 100% encapsulated electronics. The sensor electronics are completely protected and immune to water ingress and corrosion. The gas detector sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. Model Series 700 intelligent sensor modules feature dual redundant outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output.

Electrical Classification (FP, TP, IR Series)
Class I, Div 1, Groups B, C, D; Class I, Zone 1, Group IIB+H2 (ATEX)

Electrical Classification (DM, O2, PI Series)
Class I, Div 1, Groups A, B, C, D; Class I, Zone 1, Group IIC (ATEX)

Safety Approvals
CSA/NRTL (US OSHA Certified)
ATEX

Other Documentation




Model TP-700


Description
Detcon Model TP-700 Hydrogen Sulfide sensors are non-intrusive “Smart” sensors designed to detect and monitor H2S in air over the range of 0-100 ppm. The sensor assembly consists of a proprietary solid state metal oxide semiconductor in an electropolished 316SS housing, an encapsulated Intelligent Transmitter Module, and sensor splashguard with integral cal port. Operator interface is via a small handheld magnet. One of the main features is the embedded intuitive software that guides the user through routine calibration and configuration menus using a built-in LED alpha/ numeric display.

Datasheet



Model FP-700



Description
Detcon Model FP-700 Combustible Gas sensors are non-intrusive “Smart” sensors designed to detect and monitor Combustible Gas in air over the range of 0-100% LEL (lower explosive limit). The sensor assembly consists of a matchedpair catalytic bead in an electropolished 316SS housing, an encapsulated Intelligent Transmitter Module, and sensor splashguard with integral cal port. Operator interface is via a small handheld magnet. One of the main features is the embedded intuitive software that guides the user through routine calibration and configuration menus using a built-in LED alpha/numeric display.

Datasheet



Model IR-700-CH



Description
Detcon Model IR-700-C H Combustible Gas sensors are non-intrusive “Smart” sensors designed to detect and monitor Combustible Hydrocarbons in air over the range of 0-100% LEL (lower explosive limit). The sensor assembly consists of a miniature infrared optical sensor in an electropolished 316SS housing, an encapsulated Intelligent Transmitter Module, and sensor splashguard with integral cal port. Operator interface is via a small handheld magnet. One of the main features is the embedded intuitive software that guides the user through routine calibration and configuration menus using a built-in LED alpha/ numeric display.

Datasheet



Model DM-700-CO



Description
Detcon Model DM-700-CO Carbon Monoxide sensors are non-intrusive “Smart” sensors designed to detect and monitor CO in air over the range of 0-100 ppm. The sensor assembly is constructed of electropolished 316SS and consists of two parts — an encapsulated universal Intelligent Transmitter Module (ITM), and a plug-in electrochemical cell with intelligent sensor interface. The plug-in intelligent sensor automatically identifies itself to the ITM and allow s for seamless field interchangeability. Operator interface is via a small handheld magnet. One of the main features is the embedded intuitive software that guides the user through routine calibration and configuration menus using a built-in LED alpha/numeric display . Included is a splashguard with integral cal port.

Datasheet



Model DM-700-O2



Description
Detcon Model DM-700-O2 Oxygen sensors are non-intrusive “Smart” sensors designed to detect and monitor Oxygen in air over the range of 0-25% by volume. The sensor assembly consists of an electrochemical sensor in an electropolished 316SS housing, an encapsulated Intelligent Transmitter Module, and sensor splashguard with integral cal port. Operator interface is via a small handheld magnet. One of the main features is the embedded intuitive software that guides the user through routine calibration and configuration menus using a built-in LED alpha/numeric display.

Datasheet



Model PI-700



Description
Detcon Model PI-700 sensors are nonintrusive “Smart” sensors that use photoionization detector technology to monitor VOC gases over ranges from 0-10 ppm to 0-5,000 ppm. In the PI-700 sensor design, Detcon has successfully converted the sensitiv e laboratory style PID technology into a rugged, environmentally insensitive, and long-life industrial gas sensor. The sensor assembly consists of plug-in replaceable miniatur e PID sensor in an electropolished 316SS housing, an encapsulated Intelligent Transmitter Module, and sensor splashguard with integral cal port. Operator interface is via a small handheld magnet. One of the main features is the embedded intuitive software that guides the user through routine calibration and configuration menus using a built-in LED alpha/numeric display.

Datasheet




 Detcon MicroSafe™ Gas Detection Sensors

"Intuitive Diagnostic Intelligence"

  • Intuitive Non-intrusive Operator Interface
  • Modular Plug & Play Sensors & Transmitters
  • Simple Menu-driven Calibration & Programming
  • Integral Sensor Fault Diagnostics

Two Models to Choose From

  • Model 500: 4-20mA
  • Model 600: 4-20mA, Modbus RTU, Alarm Relays

Detcon MicroSafe™ Series intelligent gas detection sensors feature Detcon's MicroSafe™ intuitive software. Operator interface is non-intrusive using a hand-held magnet and program switches accessed through a glass lens cover. Calibration instructions appear in simple interactive and sequential script on a 16-character backlit alphanumeric display. The transmitter design incorporates extensive fault diagnostics with each condition conveniently identified on the transmitter display. The gas detector sensor elements and transmitters are plug-in components and can easily be replaced in the field.

Model Series 500 comes standard with a linear 4-20 mA output, one-man remote calibration, self-adjusting zero and span, and LED indicators for fault and calibration status.

Model Series 600 includes the same features as the 500 with the addition of 3 alarm relays and an RS-485 serial communications port.

Electrical Classification - Explosion proof
Class I, Div 1, Groups B, C, D

Safety Approvals
CSA and UL Approved

Other Documentation




Model TP-624C - Solid State H2S Chemfet MOS (TP)



Description
Detcon Model TP-624C Hydrogen Sulfide sensors are non-intrusive “Smart” sensors designed to detect and monitor H2S in air over the range of 0-100 ppm. The sensor assembly consists of a proprietary solid state metal oxide semiconductor sensor in a stainless steel housing, a plug-in control transmitter circuit, a base connector board and an explosion proof enclosure.

Datasheet



Model FP-624C - Combustilble Gas Catalytic Bead (FP)



Description
Detcon Model FP-624C sensors are nonintrusive “Smart” sensors designed to detect and monitor Combustible Gas in air over the range of 0-100% LEL (lower explosive limit). The sensor assembly consists of a matched-pair catalytic bead sensor in a stainless steel housing, a plug-in control transmitter circuit, a base connector board and an explosion proof enclosure.

Datasheet



Model IR-622 - Combustible Hydrocarbons Infrared (IR)



Description
Detcon Model IR-622 sensors are nonintrusive “Smart” sensors designed to detect and monitor Combustible Hydrocarbons over the range of 0-100% LEL (lower explosive limit). The sensor assembly consists of a miniature infrared optical sensor in a stainless steel housing, a plug-in control transmitter circuit, a base connector board and an explosion proof enclosure.

Datasheet



Model IR-640 - Carbon Dioxide CO2 Infrared (IR)



Description
Detcon Model IR-640 sensors are nonintrusive “Smart” sensors designed to detect and monitor Carbon Dioxide. Available ranges of detection are 0-0.3%, 0-1%, 0-3%, and 0-5% by volume. The sensor assembly consists of a miniature infrared optical sensor in a stainless steel housing, a plug-in control transmitter circuit, a base connector board and an explosion proof enclosure.

Datasheet



Series 500IS - Toxic Gases Electrochemical (DM)



Description
Detcon Model DM-500IS-CL2 sensor is designed to detect and monitor CL2 in air over the range 0-10 ppm. The sensor assembly consists of an electrochemical fuel cell mounted in an Intrinsically Safe stainless steel and ABS plastic housing that includes an integral rain-shield, a signal conditioning control transmitter circuit, a base connector board and an explosion proof junction box. The Intrinsically Safe sensor housing design allows direct contact of the target gas to the electrochemical sensor, thus maximizing response time, detectability and repeatability. And because the Intrinsically Safe housing design does not use a stainless steel flame arrestor, it eliminates inaccurate readings due to target gas absorption.

Datasheet



Model DM-634 - Oxygen Deficiency (O2)



Description
Detcon Model DM-634 sensors are non-intrusive “Smart” sensors designed to monitor ambient air for concentrations of Oxygen in the range 0-25% by volume. The sensor assembly consists of a sensor in a stainless steel housing, a plug-in control transmitter circuit, a base connector board and an explosion proof enclosure.

Datasheet




 Detcon UniTox™ Gas Detection Sensors

"One Universal Transmitter that adapts to any Intelligent Sensor Module"

  • Intrinsically Safe Design
  • 2-Wire Loop Powered
  • Plug & Play Field Exchangeable Intelligent Sensor Modules
  • Stainless Steel Intelligent Sensor Module Housings
  • Modules for Up to 40 Different Gas Types Available
  • Non-Intrusive and Simple Menu Interface
  • Built-in System Diagnostics

Detcon UniTox™ gas detection sensors are designed around a Universal Transmitter and a series of Intelligent Sensor Modules. The UniTox™ product group includes sensors for the detection and monitoring of approximately 40 toxic gases (plus oxygen). Calibration and periodic maintenance can be performed in place or by moving the intelligent sensors modules to a safe area for service and calibration minimizing the time plant personnel are required to work in potentially hazardous areas.

The Intrinsically Safe UniTox™ sensors are two-wire loop-powered field devices that use advanced microprocessor technology to the convert the signal from an electrochemical sensor to a linear 4-20 milliamp output. Digital communication between Intelligent Sensor Modules and the Universal Transmitter Module include data strings representing gas type, range of sensitivity and last calibration date. Peak reading values and time weighted average for the last 8 hours of operation are stored in the Universal Transmitter Module.

Electrical Classification
NEMA 4X Class 1, Div. 1, Groups A, B, C, D; EEx ia IIC T3C
CE Marking

Other Documentation




Model DM-200XP-O2 - DM-200XP-O2 Oxygen Sensor Assembly



Description
Detcon Model DM-200XP-O2 is specifically designed to detect and monitor O2 in air over the range 0-25 %. It is one of a complete group of toxic gas detection sensors based on electrochemical sensor technology. The sensor assembly consists of an Intelligent Sensor Module packaged in a stainless steel housing and a Universal Transmitter Module packaged in an explosion proof enclosure. Its universal design allows complete interchangeability of any Intelligent Sensor Module with any Universal Transmitter Module. Model Series 200 sensors are 2-wire loop powered with a linear 4-20 milliamp output.

Datasheet



Model DM-200XP-H2 - Hydrogen Sensor Assembly (ppm Range)



Description
Detcon Model DM-200XP-H2 is specifically designed to detect and monitor H2 in air over the range 0-100 ppm. It is one of a complete group of toxic gas detection sensors based on electrochemical sensor technology. The sensor assembly consists of an Intelligent Sensor Module packaged in a stainless steel housing and a Universal Transmitter Module packaged in an explosion proof enclosure. Its universal design allows complete interchangeability of any Intelligent Sensor Module with any Universal Transmitter Module. Model Series 200 sensors are 2-wire loop powered with a linear 4-20 milliamp output.

Datasheet



Model DM-200XP-C2H3O - DM-200XP-C2H3O Acetyldehyde Sensor Assembly



Description
Detcon Model DM-200XP-C2H3O is specifically designed to detect and monitor C2H3O in air over the range 0-100 ppm. It is one of a complete group of toxic gas detection sensors based on electrochemical sensor technology. The sensor assembly consists of an Intelligent Sensor Module packaged in a stainless steel housing and a Universal Transmitter Module packaged in an explosion proof enclosure. Its universal design allows complete interchangeability of any Intelligent Sensor Module with any Universal Transmitter Module. Model Series 200 sensors are 2-wire loop powered with a linear 4-20 milliamp output.

Datasheet




 Sample Draw Manifolds



Detcon Model SD-1-N4X - General Purpose NEMA 4X, Weatherproof



Detcon Model SD-1-N4X is a single sensor sample draw manifold designed for use with any one of a number of gas detection sensors including combustible gas, hydrogen sulfide, oxygen and a long list of toxic compounds. The sampling system utilizes an internal pump to draw air and gas samples from a remote location and flow the sample across the sensor at a metered flow rate. In use, the sample draw method allows for remote calibration and routine maintenance without exposing maintenance personnel to dangerous or difficult to access sampling areas. Sampling time is a function of the distance between the sample point and the sample draw manifold. Detcon Model SD- 1-N4X is housed in a NEMA 4 weatherproof enclosure and is suitable for installation in outdoor locations. The non-hazardous area rating allows for installation with a minimum distance to the sample point, which decreases delays in real time sampling.


Datasheet



Detcon Model SD-1-N7 - NEMA 7 Explosion Proof



Detcon Model SD-1-N7 is a single sensor sample draw manifold designed for use with any one of a number of gas detection sensors including combustible gas, hydrogen sulfide, oxygen and a long list of toxic compounds. The sampling system utilizes an internal pump to draw air and gas samples from a remote location and flow the sample across the sensor at a metered flow rate. In use, the sample draw method allows for remote calibration and routine maintenance without exposing maintenance personnel to dangerous or difficult to access sampling areas. Sampling time is a function of the distance between the sample point and the sample draw manifold. Detcon Model SD-1-N7 is housed in a NEMA 7 explosion proof enclosure and is suitable for installation in hazardous locations: Class I; Division 1; Group C & D. The hazardous area rating allows for installation with a minimum distance to the sample point, which decreases delays in real time sampling.

Datasheet




 Calibration Equipment



Kits, Regulators, Adapters, & Calibration Gas Cylinders



Detcon Calibration Gas Kits consist of a polyester saddle bag that holds up to 2 calibration gas cylinders. The bag includes a detachable padded shoulder strap and padded handle grip. Several pockets provide space for additional components that include an in-line humidifyer tube (used only for solid state H2S sensor), fixed flow regulator, and length of tubing. Regulators and tubing will vary depending on type of gas being used (see descriptions below). Calibration Gas Kits do not include calibration gas cylinders or calibration adaptors which are ordered separately.

Datasheet